Mikrocomputer Magnetventil Controller Narr Pneumatische Magnetventil Schalt Zeit Relais Integrierte Zylinder Control Box

83,90 €

inkl. 19 % MwSt. auf die Ware; bestätigter Versand nach Deutschland enthalten

Lieferung nach Deutschland
Lieferzeit: 8–15 Tage

Angezeigter Planpreis. Bestellungen sind noch nicht freigeschaltet.

Produktbeschreibung

Only four controllers are programmable
A total of nine commands can be edited
0 means no power 1 means power on
The manual test is a cycle of actions
Fully automatic is an infinite loop
The number of segments that do not require action is replaced by time 0, so there will be no separate time
For example: four-way controller, it intelligently controls four-way output and takes care of itself. It cannot identify whether there are other faults, and it will cycle continuously according to the set time. You can set the time to repeat within different seconds (99 seconds) for the four solenoid valves. Action. It is more suitable for more mechanical occasions.
In addition, it can be programmed with four-way commands. There are 9-terminal commands that can be set. Example: 1 2 No. 34 solenoid valve. You can set the command 1111, then the four output the second command in No. 1 at the same time. It takes 2 3 moves, then it is 0110 in In No. 2, the 9-end is a loop, you can only take a few of them
Programmable Controller Instructions
1: Interface and button description
The five-digit digital tube in the first row displays the count (in the editing state, the output action is displayed: 1 means the output is powered on, 0 means the output is powered off), the second row of a single-digit digital tube displays the number of segments of the output command, and the three-digit digital tube displays Output action time, the time range is 0~99.9 seconds. From left to right, the 5 indicators are manual mode, semi-automatic mode, fully automatic mode, debugging mode, and power indicator. The buttons on the surface of the controller are, from left to right, edit, subtract down, add up, switch mode, clear the count, and end the emergency stop. On the side is the power switch.
Edit: Press and hold for 2 seconds to enter the editing state, tap to enter the next command in the editing state
Down-minus key: In the editing state, the time is decreased and the output action is decreased. In the standard state, decrease the number of segments to check the state and time of the action
Up key: In the editing state, the time is added and the output action is added. In the standard state, add the number of segments to view the state and time of the action
Mode switch: In the editing state, the editing digits are shifted to the left. In the standard state, the mode of the output action is switched.
Clear the count: in the editing state, the editing digit is shifted to the right. In the standard state, long press the count reset button for 2 seconds, the count times will be reset
The output action and action time are not cleared.
End of emergency stop: In the editing state, save the program after pressing the key. In the standard state, after pressing the button, the output action of the controller will stop immediately.
The action returns to the first output action. Press and hold the emergency stop button for 2 seconds, the controller enters the sleep standby state, and the program count is not cleared.
Two: Operation Instructions

Produktdetails in Bildern

Mikrocomputer Magnetventil Controller Narr Pneumatische Magnetventil Schalt Zeit Relais Integrierte Zylinder Control Box – Detail 1 Mikrocomputer Magnetventil Controller Narr Pneumatische Magnetventil Schalt Zeit Relais Integrierte Zylinder Control Box – Detail 2

Produkteigenschaften

Markenname
AIRSLG
Ursprung
CN (Herkunft)
Hochbetriebenes Chemikalienunternehmen
Keine
Typ
Ventil
Motivitätstyp
Sonstiges
Zertifizierung
NONE

Artikelnummer: 1005004012476418